PC DYNAMICS free chlorine/redox/pH
PC DYNAMICS free chlorine/redox/pH with 2 dinodos START
Article no. 0133-080-90

PC DYNAMICS
Microprocessor-controlled measuring and control device, optionally for redox / pH or Poolcare | (time-controlled) / pH, in splash-proof plastic housing, wired ready for connection 230 V/50 Hz. Display of measuring values on backlit graphical display with alphanumeric characters. Menu navigation via plain text display with selection of the appropriate language. Operating status, warning and alarm messages in plain text via the status bar on the display. |
Compact measuring and control device for the measuring options: | |
- | redox, pH, temperature and sample water deficiency Poolcare (time-controlled), pH, temperature and sample water deficiency |
Free switching between measurement options. | |
By an additional installation of a „potentiostatic measuring board for the Poolcontrol DYNAMICS," it is possible to integrate further measuring options. | |
Characteristics of the system unit | (in wall mounting case) for disinfection and dosing equipment: Microprocessor-controlled measuring and control device IP 65 Clear graphics display Logical menu structure for an easy adjustment of set points, limit values and parameters Configuration menu for selection of measurement technology and other functions Password protection to prevent unauthorised operation Multilingual system / language selection Measuring input for measurement of redox Measuring input for measurement of pH Measuring input temperature measurement Integrated standard controls for disinfection, pH correction pH reduce and pH raise can be connected simultaneously Control of pH raise or flocculant dosing optional Automatic switch-on delay Sample water control Dosing time control Empty warning contact for container fill level Integrated alarm relay Interfaces for connection to dinowin and dinotecNET+ Analog output for output of hygiene parameters |
Measuring cell P304
Closed, pressure-proof compact measuring cell made of transparent plastic on white PVD plate, for a potentiostatic measurement of free chlorine / Poolcare as well as pH, redox, temperature and sample water monitoring. The measuring cell contains the pre-mounted counter-electrode for potentiostatic measurement methods. The measuring water supply can be controlled via a ball valve and bypass. Integrated flow control monitoring module for connection to the measuring device. Screw connection for temperature sensor PT1000. Return of the sample water into the water circulation is planned.Fibre filter
Fiber filter ¾" with screening pipe for retaining impurities in the sample water to prevent entry in the measuring cell. Fiber filter including screw connections for sample water pipes and securing clamps for mounting on a plate.Measurement accessories
Measuring accessories for measurement of the parameters chlorine, redox and pH. | |
This includes: | |
1x potentiostatic probe for free chlorine | |
1x redox probe without reference system | |
1x pH probe | |
1 x cleaning material liquid | |
1 x special cleaning paste | |
1 x calibration solution pH 4.0 - 50 ml | |
1 x calibration solution pH 7.0 - 50 ml |
dinodos START pump
Microprocessor-controlled peristaltic dosage pump for an automatic addition of any kind of liquid media, even minimum quantities. With stepper motor and continuously variable digital speed control. Continuous operation with an applied mains voltage of 230V. Activation by the press of a key, switching contact (ON/OFF), current (0 (4)-20 mA, ascending or descending linearly) and frequency control
The pump offers a wide-ranging capacity from 45 ml/h up to 9.0 l/h at a maximum counter pressure of 1.5 bar. The delivery rate is infinitely variable via the control or the two potentiometers on the pump.
With integrated dosage pump hose (d 8 mm) and hose connector (4/6 mm).
Input for empty signal containers and failure output are available, a broken pipe is detected automatically. The pump is safe for continuous operation and features a thermal protection.
It can be easily ventilated by the touch of a button and can dose at 100 percent capacity for a minute also by pressing a button.
The operating conditions are signalled via LEDs.TD Dynamics single device
Technical data | |
System housing: | Plastic housing, protection class: IP 65 |
Dimensions system housing: | 260 x 260 x 85 mm (w x h x d) |
Weight: | approx. 1.5 kg |
Mains voltage: | 115 / 230 V/AC, 48-63 Hz |
Power consumption: | 10 VA (w/o dosing equipment) |
Display: | via large graphical display 100 x 30 mm |
Operation: | Plain text menu with keys |
Language: | Language selection |
Operating temperature: | 5 to +40 °C |
Storage temperature: | - 20 to + 65 °C |
Rel. humidity: | max. 90 % at 40 C°, non-condensing |
Safety management: | - Input dosing stop (e.g. flow sensor) - Monitoring of sample water flow - Common alarm / alarm relay - Alarm message in display as plain text - Flashing display illumination for signalling an alarm condition - Dosing time control |
Interfaces | |
RS 485: | for linking to dinowin / Profibus Gateway / etc. |
dinotecNET+: | for connection to dinotecNET+ as field device |
Redox measuring amplifier | |
Measuring range: | -1500 mV to +1500 mV |
Resolution: | 1 mV |
Ambient temperature influence: | 50 ppm/K (12 mV) |
Reference temperature: | 23 °C |
Input resistance: | > 1012 ohm |
Redox measurement: | via combination electrode without reference system |
Calibration: | not required |
pH measuring amplifier | |
Measuring range: | -1500 mV to +1500 mV |
Resolution: | 0.01 pH or 1 mV |
Ambient temperature influence: | 50 ppm/K (12 mV) |
Reference temperature: | 23 °C |
Input resistance: | 1012 ohm |
Calibration pH: | optionally one-point or two-point calibration |
Electrode check: | automatically after calibration |
Temperature compensation | |
of pH value: | automatic with PT1000 or manual adjustment |
Temperature | |
Temperature input for measuring sensor: | PT1000 |
Measuring range: | 0 to +60 °C (+/-1%) |
Inputs/outputs, control response | |
Type of control: | P, PI, or PID control optionally |
Control: | optionally 1-step or 2-step controller |
Binary outputs: | 4 potential-free output relays for chlorine, pH reduce and pH raise (pulse length, pulse frequency (On/Off), alarm. |
Alternative to pH raise: | Flocculant dosing On/Off/ |
Maximum contact load | |
(230V AC): | 370 W (inductive), 500 W (Ohm resistive load) |
Max. switching current: | 30V/10A, 115V/0.3A, 230V/0.12A |
Digital inputs: | Empty warning chlorine, pH reduce, dosing stop |
Analog output: | 0(4) - 20 mA for individual measuring values (optional) |
Cable cross section | |
terminal: | 0.5 - 2.5 mm² |
Measuring cell P304
Technical data | |
Threaded connection for measuring probes: | PG 13.5 |
Threaded connection for PT 1000: | R ¼" |
Flow monitoring module: | Reed contact with 2-wire cable connection |
Min. initial pressure: | 0.1 bar |
Max. counter pressure: | 1 bar |
Sample water demand: | 120 l/h |
Connection supply and drain: | PVC hose 6/8 mm |
Material: | Acrylic glass, clear, with wall mount |
Dimensions: | 80 x 310 x 82 (wxhxd) |
Fibre filter
Technical data | |
Connections fiber filter: | Internal thread ¾" |
Screening pipe - material: | Nylon in plastic cage |
Mesh size of screening pipe: | 0.5 mm |
Double-sided | |
screw connections: | PVC hose 8/6 mm |
Pipe clamps for fiber filter: | DN30 |
TD for measurement accessories
Technical data | |
Operating temperature: | 0 - + 45 °C |
Rel. humidity: | max. 90 % at 40 °C, non-condensing) |
Storage temperature: | + 20 to + 65 ° C |
dinodos START pump
Technical data | |
Mains voltage: | 230 V , 50/60 Hz |
Power consumption max.: | approx. 16 VA |
Protection class: | IP 65 |
Dimensions housing (w x h x d): | approx. 170 x 90 x 130 mm |
Weight of pump: | approx. 1.5 kg |
Permissible ambient temperature: | +10 to +45 oC |
Drive: | Stepper motor |
Pump hose: | compl. with connection pieces for suction line 4/6 |
Capacity max.: | approx. 0.045 - 9.0 l/h (infinitely adjustable) at a counter-pressure of max. 1.5 bar. |
Speed range: | 0.01 rpm up to 100 rpm |
Frequency range pulses: | 0.02 pulse/sec. - 1 pulse/sec. |
Suction lift max.: | 1.80 m |
Operation: | output infinitely adjustable via two potentiometers |
Drive (I): | via voltage free contact input (NOC) |
or drive (II): | via power input 4-20 mA (4mA=0%, 20mA=100%) |
or drive (III): | via power input 20-4 mA (4mA=100%, 20mA=0%) |
or drive (IV) | Frequency control |
Empty warning connection: | Normally closed contact / normally open contact (switchable) |
Hose leak detection: | Integrated contacts in pump housing |