Skip to main content
  • 20131202_123953.jpg
  • 20140417_133326.jpg
  • 20150717-img_0557-hdr.jpg
  • 81639448163950-2.jpg
  • aussenansicht_c_rogner_bad_blumau.jpg
  • dscf4071.jpg
  • dsc_0878.jpg
  • dsc_1016.jpg
  • elsinger_006.jpg
  • elsinger_013.jpg
  • fotolia_35884874_xxlb.jpg
  • gph-08-09-08.jpg
  • gph-08-09-18.jpg
  • plastex452008_0015.jpg
  • tesselles_gris.png

Headline

Headline

Headline

Yellow Poolcontrol

SIMPLY. MORE.  INSPIRING.

  • space.png

Yellow

Poolcontrol

SIMPLY. MORE.  INSPIRING.

Experience The Yellow live! Make an appointment with the dinotec specialist dealer near you

Or visit us at the following trade fairs; we look forward to seeing you!

  • Interbad in Stuttgart: October 6 to 8, 2026
  • Piscine in Lyon: November 17 to 20, 2026
Yellow Poolcontrol wins Golden Wave Award 2026 in the Usability category

Our Yellow Poolcontrol was awarded the renowned Golden Wave Award 2026 in the Usability category. The innovation award is presented by the trade magazine SCHWIMMBAD+SAUNA and is one of the most important awards in the pool and wellness industry in the German-speaking region.

The jury particularly recognized the consistent focus on user-friendliness: Yellow Poolcontrol impresses with intuitive operation, clear structures, and efficient control in daily use – both for swimming pool builders and end customers.

The award ceremony took place on March 27, 2026, at the Rulantica water park in Europa-Park Rust and provided the perfect setting for honoring outstanding innovations in the industry.

The Golden Wave Award is presented every two years and recognizes innovative products, technologies, and processes that have a lasting impact on pool and wellness construction.

We thank the jury for this special recognition as well as our entire team, which worked with great commitment and passion on the development of Yellow Poolcontrol has worked.

“This award confirms our commitment to making complex pool technology as simple and accessible as possible. With the Yellow Poolcontrol we have developed a solution that consistently combines technology and user-friendliness – and that is exactly what has now been recognized.”

Ralph Ziegler, Managing Director

Documents
Quick guide

Drilling template language set 1

Drilling template language set 2 (CZ, RS, TH, SL)

Miscellaneous
Interface Mapping Documentation

# Interface Mapping Documentation - Yellow Poolcontrol

This documentation describes the data points for the external interfaces **MQTT**, **BAOS (KNX)**, and **Modbus TCP/RTU**.

## Addressing Scheme
- **Modbus:** All addresses are holding registers (4xxxx).
- **BAOS (KNX):** IDs correspond to KNX object numbers.
- **MQTT:** The base topic is configurable (`mqtt_topic`, default: `Netplus`).
- **Scaling:** Analog values are transmitted as integers. A factor of 100 means the value must be divided by 100 (e.g., 720 -> 7.20).

## MQTT Behavior

### Topic Structure
- **baseTopic:** Please refer to the MQTT settings of your device for the base topic (default: `netplus`).
- **State topic (read):** `/`
- **Command topic (write):** `//set`
- Example: With `baseTopic=Netplus` and `topic=flag.system.enable`:
  - Read: `Netplus/flag.system.enable`
  - Write: `Netplus/flag.system.enable/set`

### Payload Format
- Encoding: UTF-8
- QoS: `1`
- Retain: `false`
- Boolean values: `true/false` or `1/0` (incoming `true` or `1` is interpreted as `True`).
---

### 1. System Status (General)
| Data Point | MQTT | BAOS ID | Modbus | Type | Scaling | Description |
| :--- | :--- | :--- | :--- | :--- | :--- | :--- |
| `flag.system.enable` | `rw` | 1 | 40001 | Bool | - | Main system switch (On/Off) |
| `flag.system.ready` | `r` | 3 | 40002 | Bool | - | System ready for operation |
| `flag.error` | `r` | 2 | 40003 | Bool | - | Collective alarm active |

### 2. Measurements (Actual Values)
| Data Point | MQTT | BAOS ID | Modbus | Type | Scaling | Description |
| :--- | :--- | :--- | :--- | :--- | :--- | :--- |
| `variable.temperature.actualValue` | `r` | 101 | 40101 | Int | 100 | Water temperature (°C) |
| `variable.ph.actualValue` | `r` | 102 | 40102 | Int | 100 | pH value |
| `variable.chlorine.actualValue` | `r` | 103 | 40103 | Int | 100 | Free chlorine (mg/l) |
| `variable.redox.actualValue` | `r` | 104 | 40104 | Int | 1 | Redox potential (mV) |
| `variable.activeChlorine.actualValue` | `r` | 105 | 40105 | Int | 100 | Active chlorine HOCl (mg/l) |
| `variable.flow.actualValue` | `r` | 106 | 40106 | Int | 1 | Measuring water flow (l/h) |

### 3. Setpoints (Settings)
| Data Point | MQTT | BAOS ID | Modbus | Type | Scaling | Description |
| :--- | :--- | :--- | :--- | :--- | :--- | :--- |
| `setpoint.phLower.setpoint` | `rw` | 201 | 40201 | Int | 100 | pH lowering setpoint |
| `setpoint.phRaise.setpoint` | `rw` | 202 | 40202 | Int | 100 | pH raising setpoint |
| `setpoint.chlorine.setpoint` | `rw` | 203 | 40203 | Int | 100 | Chlorine setpoint |
| `setpoint.temperature.setpoint.normal` | `rw` | 204 | 40204 | Int | 100 | Temperature setpoint |
| `setpoint.redox.setpoint` | `rw` | 205 | 40205 | Int | 1 | Redox setpoint |

### 4. Control & Actuators
| Data Point | MQTT | BAOS ID | Modbus | Type | Scaling | Description |
| :--- | :--- | :--- | :--- | :--- | :--- | :--- |
| `flag.disinfection.automatic` | `rw` | 301 | 40301 | Bool | - | Automatic disinfection |
| `flag.phLower.controller.mode` | `rw` | 302 | 40302 | Bool | - | Automatic pH control |
| `flag.temperature.automatic` | `rw` | 303 | 40303 | Bool | - | Automatic heating |
| `actuator.circulationPump` | `r` | 304 | 40304 | Bool | - | Circulation pump status |
| `variable.ecoTouch.stage` | `r` | 309 | 40309 | Int | 1 | Current pump stage (0-3) |
| `actuator.light1` | `rw` | 305 | 40305 | Bool | - | Pool lighting On/Off |
| `flag.partyMode.active` | `rw` | 306 | 40306 | Bool | - | Party mode On/Off |
| `flag.ecoMode.active` | `r` | 307 | 40307 | Bool | - | ECO mode active (status) |
| `flag.holidayMode.enable` | `rw` | 308 | 40308 | Bool | - | Holiday mode On/Off |
| `flag.frostProtection.enable` | `rw` | 310 | 40310 | Bool | - | Frost protection On/Off |

### 5. Alarms & Maintenance
| Data Point | MQTT | BAOS ID | Modbus | Type | Scaling | Description |
| :--- | :--- | :--- | :--- | :--- | :--- | :--- |
| `flag.disinfection.containerEmpty.message` | `r` | 401 | 40401 | Bool | - | Disinfection container empty |
| `flag.phLower.containerEmpty.message` | `r` | 402 | 40402 | Bool | - | pH container empty |
| `flag.circulation.fault` | `r` | 403 | 40403 | Bool | - | Flow fault / circulation fault |
    